The evolution of the IOCCO Bag Furnace reduces the energy required for vacuum bag treatment while maintaining the thermodynamic and vacuum requirements of the process.
Around six months of continuous monitoring across the two furnace generations recorded an average consumption per operating hour of 459 kWh for the previous generation and 340 kWh for the new one: 119 kWh less per hour, a 25.9% reduction. Monitoring covered all eight new-generation furnaces installed in the United States, Mexico, Belgium and Luxembourg.
Assuming 353 operating days at 24 hours per day, projected savings are about 1.008 GWh per furnace and 8.065 GWh per year across the eight furnaces. These are calculated annual figures, not measured annual totals: consumption depends on product, recipe and operating conditions.